-
WarpAxe v0.1.35
Stablereleased this
2026-10-22 09:07:07 +00:00 | 223 commits to main since this releaseNothing changes for miners that already run WarpAxe. A board set up by an earlier version is taken as verified on the update and starts as before. What follows applies to a first start, a board chosen anew, or a check you ask for.
A board is checked before its chips get power. On a first start the web UI lists only the boards that fit what answered on the miner's I²C bus; Show all boards reveals the rest, with a warning. Whatever is chosen, the firmware checks it against the bus at the next start before it drives any of the board's pins: the voltage regulator, the sensors and the other parts that board must have, and the ones it must not have. A board that does not fit is refused, its chips stay off, and the web UI says why (for example which part did not answer) and lists the boards that do fit. A missing sensor on a newly chosen board is refused as well.
A cautious first start, then a count. A board that passes the check starts its chips at a cautious voltage, the lowest of the boards that look alike on the bus, and counts them. If their number and type match the board, it counts as verified: the configured voltage applies, and the self-test runs once by itself about 20 seconds later. Another board's chip count, a chip of another type or no chips at all switch the chips off again and show the reason, with Restart and try again or the choice of another board. Fewer chips than the board has, where no look-alike board has that count, only bring a warning (a dead chip, not a wrong board). This applies to boards the detection found as well as to boards chosen by hand. To put a verified board through the check again on purpose:
PATCH /api/systemwith{"boardModel": "<its name>", "reverify": true}, then restart. Details:docs/11-Board-choice-guard.md.The BitForge Nano and the NerdAxe Gaia are found without asking. The Nano is taken when its PCA9544 mux, INA260 and TPS546 answer on the bus; the Gaia when its TPS546 and EMC2101 answer and the regulator reads 12 V at its input. The same parts at 5 V are a NerdAxe Gamma, which is still offered for one click. The Nano, the Gaia and the NerdNOS, which have been on our bench for weeks, are no longer marked "not yet tested with WarpAxe".
The event log in your language. The details of each event (restart reasons, pool switches, board checks, overheat stops, regulator faults, self-test results) are now shown in the web UI's language. The API and the diagnostics file keep the English text in
dword for word, so tools reading it see no change; new optional fieldscandpcarry a short code and the values.Smaller things. When a first start or a check reads the bus, the regulator's input voltage gets a log line of its own, in volts.
Tested on 2026-10-22 on a NerdAxe Gaia and a BitForge Nano: first start, chips counted and verified, self-test PASS with 9 of 9 checks. New strings in eight languages, translated and then read by independent editors.
One image for every supported board:
warpaxe.bin,warpaxe.bin.sha256,warpaxe.bin.sig,tested-on.txt; for the first installwarpaxe-factory.binandweb-flasher.tar.gz(checksums ininstall.sha256).